Serial Clock/Timer Connections between CT2002 stand-alone Models
Master/Slave Interconnection via Twisted Pair Connections
FOR MASTER TIME SYNC VIA TOP-of-HOUR RESET
wire timer displays Top-of-Hour in for accurate time readout.
Note: T.O.H. input must be used to offset timer by one or more
seconds. Use IR remote control progam option 10 consult
manual page 11 for more information.
FOR MASTER TIME SYNC VIA RADIO SYSTEMS or SMPTE SERIAL DATA
wire timer displays serial in with Radio Systems or SMPTE Time-of-Day
serial input for accurate time readout. Accurate time will be read by all
serially connected displays. Time may be offset by one or more hours
- use IR remote control progam option 4 consult manual page 10 for
more information.
CT-2002 4” & 2”, Desktop or Thin (Thin Shown)
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
GND
DOWN TIME CLOSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-45 IN
9V DC IN
MODEL CT-2002 DESKTOP Part No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SHIELD TO GND
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 Desktop
GND
SERIAL OUT -
SERIAL OUT +
GND
START SWITCH
STOP SWITCH
RESET SWITCH
MODE SWITCH
GND
TIME CLOSURE 1
TIME CLOSURE 2
TIME CLOSURE 3
TIME CLOSURE 4
GND
DOWN TIME CLOSURE AT “0”
TOH RESET INPUT
RJ-45 OUT
RJ-45 IN
9V DC IN
MODEL CT-2002 DESKTOP Part No. 14409
SERIAL IN +
SERIAL IN -
RJ-45 SHIELD TO GND
Logan Township, New Jersey USA
1-856-467-8000 • www.radiosystems.com
CT-2002 4” & 2”,
Desktop or Thin (Desktop Shown)
Connect serial inputs
in parallel to slave
downstreamTime-of-
Day displays only.
Connect serial output to
downstream clocks’ serial input
to slave Time-of-Day and timer
readouts, or if this is the master
(first) clock in the serial chain.
Connect serial inputs
in parallel to slave
downstreamTime-of-
Day displays only.
Repeat up to 35 displays.
Note: final display serial line
must be terminated with a
150 resisitor (use terminator
DIP switch on large clock.)
Connect serial output to downstream
clocks’ serial input to slave Time-of-Day
and timer readouts, or if this is the master
(first) clock in the serial chain.
PC Clock Input Sync
Note: Software/hardware
kit available (Radio Systems
part # 16117) to update
Windows PC clocks via USB
from the CT-2002
serial data stream
DOWN TIME CLOSURE AT “0”
+9V DC IN
GND
GND
START SW
STOP SW
RESET SW
MODE SW
GND
SERIAL IN -
SERIAL IN +
GND
TOP OF HOUR RESET INPUT
TIME CLOSURE 4
TIME CLOSURE 3
TIME CLOSURE 2
TIME CLOSURE 1
GND
SERIAL OUT - (future use)
SERIAL OUT + (future use)
J4 J6