Radio Systems i.AM.Radio Transmitter Instruction Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 11
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
b. Select readout units in dBuV to be sure signal at the FSM input is within
the range +90dBuV to +10dBuV. Install 50 ohm pad at input to block
converter if signal strength is too high.
c. Place the FSM in Remote mode by selecting function 93 (F93) on the
meter front panel.
d. Connect the meter to the PC serial port.
e. Launch the Application by double clicking on the Desktop icon.
f. Select the GPS-enabled option within the application.
g. Attach USB GPS receiver to one of the available USB ports on the PC.
i. Launch the application and check to see that the PC is
communicating with the GPS receiver. (See the Z Technology
application note concerning communicating with a GPS receiver.)
1. After a long storage period, or when using the GPS receiver
for the first time at a new location, the receiver may take up
to ten minutes to acquire a full catalog of satellite
information. Subsequent startup times will usually be less
than one minute from turn on.
h. Observe signal strength and location readouts on screen
i. Start recording and drive in coverage area
j. Export data file to Microsoft MapPoint for a plot of signal strength, or to
Microsoft Excel for additional analysis.
k. The system will display and/or record actual field strength values at each
measurement location. It is useful to make note of surrounding conditions,
such as overhead power lines, tunnels, bridge structures, etc., that would
be expected to affect the reading.